Router - DLINK 320B: Difference between revisions
(→After each reset to factory settings: important; corrected erroneous out of date fears about VC-MUX not working) Tags: Mobile edit Mobile web edit |
(→After each reset to factory settings: cowardice : more cautious compromise) Tags: Mobile edit Mobile web edit |
||
After any reset to factory settings you will need to make the following change using the web admin user interface in order to get the device to work properly as a straight modem. (Factory default http://192.168.1.1, your own ip address set to something suitable in that same /24 subnet, username=admin, password=admin.)</p>
Choose “Bridge Mode” and “Connection type: PPPoE LLC”.
‘SETUP’ (top horizontal navigation bar) > Bridge Mode▼
▲Looking in ‘SETUP’ (top horizontal navigation bar) > Bridge Mode, you should see
<ul>
<li>1483 Bridged IP LLC.</li></ul>
Note: the leaner PPPoEoEoA + RFC2684 [obsoletes RFC1483] section 6.2 + <b>VC-MUX</b> header option (“bridged PDUs: VC-MUX”) is always more efficient than or the same as the alternative <em>LLC</em> option. The efficiency improvement depends on the length of the packets being sent and for some packet lengths the performance gain is zero. Choose 1483 bridged VC-MUX aka PPPoE VC-MUX in preference to LLC if your exchange supports it. For example, choose 1483/bridged/PPPoE VC-MUX rather than LLC if you are using a BT 21CN line.
Following this you will then also need to make the configuration changes described in the previous section.
|