Jump to content

This is the support site for Andrews & Arnold Ltd, a UK Internet provider. Information on these pages is generally for our customers but may be useful to others, enjoy!

Router - DLINK 320B: Difference between revisions

clean up, typos fixed: importent → important, ie → i.e. , etc → etc. , eg → e.g.
(clean up, typos fixed: importent → important, ie → i.e. , etc → etc. , eg → e.g.)
 
(23 intermediate revisions by one other user not shown)
<indicator name="Front">[[File:Menu-B10D.svg|link=:Category:AA_RoutersAA Routers|30px|Back up to the A&A Routers Page]]</indicator>
<h2 style="margin:0 1em 0.5em 0">Currently shipping hardware version</h2>
[[Image:DLink-DSL-320B-Z1-front-view-v2.jpg | frameless | right | 200px | alt Dlink DSL-320B-Z1 modem, front view]]
At the time of writing, December 2017, the currently shipping hardware version of the DLink DSL-320B modem/router is the DSL-320B-'''Z1'''. Confusingly, in the past DLink has described several completely different modems as “DSL‑320B”. The following sections describe the DSL‑320B‑Z1 hardware.
 
==Factory default IP, admin password==
==Default settings==
{|class="wikitable"
!colspan="2"|Default/Factory Settingsdefault web admin interface
|-
!Username:
|<code>admin</code>
|-
!Password:
|<code>admin</code>
|-
!IP:
|<code>192.168.1.1/24</code>
|}
==Notes==
*AAISP ships these devices for use as straight ethernet modems. Although they are capable of working as (buggy) routers, AA pre-configures them to work in bridge mode only, that is, in simple PPPoE modem-only mode, not operating as routers.
*TheirThe modem’s admin web interface is quite insecure and in ‘router’ mode they have various critical security bugs, which is why we do strongly suggest that customers never use them configured in 'router'‘router’ mode. They are sold by AAISP as bridge-only. Older pre-Z1 modems, such as the now obsolete pre-Z (-D1)D1” model, were shipped with their reset buttonbuttons covered to protect itthem and prevent them from being reset!
*If you reset thema modem to the factory settings using the pin-in-hole technique, then withit their factory defaults they <b>'''will not work at all</b>''' as a straight PPPoE ethernet modemsmodem while it still has its factory defaults. TheirThe configuration <b>'''must</b>''' be altered before use. Ask [https://www.aaisp.net.uk/support.html AA support] for help with this or see [[#post-factory-reset|post-factory reset configuration]] instructions below.
*No per-user or per-line login info or password configuration is required. Information concerned your ISP account or line-specific login and password info is configured in your <i>''router</i>'', and the DLink modem doesn’t need these values.
*TheyThe domodem supportsupports 1500 byte IP MTU/MRU (unlike the [[Router - ZyXEL_P660RZyXEL P660R-D1]]) by using ethernet frames with a 1500+8=1508 byte payload. (Your router will also have to support RFC 4638 and 1500+8=1508 byte MTU/MRU tooas well though for this to be effective. Note that an MTU of 1500 is not supported by BT on 20CN lines.)
*Their web interface is quite insecure and in ‘router’ mode they have various critical security bugs, which is why we do strongly suggest that customers never use them configured in 'router' mode. They are sold by AAISP as bridge-only. Older modems, the now obsolete pre-Z (-D1) model, were shipped with their reset button covered to protect it and prevent them from being reset!
*Important - '''BT 20CN''' lines: MTU 1500+8=1508 will not work on old BT 20CN lines because of BT’s limitations, nothing related to this modem.
*It is vital that you <b>not expose the LAN-side ethernet interface to users on the LAN</b> unless all possible users and devices on the LAN are trusted because of various critical security bugs in this respect. Because of such bugs, setting passwords on the modem’s admin web UI etc is not enough. If your router happens to prevent LAN-internal users from accessing the modem then so much the better, otherwise your main router’s facilities / internal firewalling and access controls should be explored.
*The modems support the ADSL standards G.992.1/G.DMT (‘ADSL1’), G.992.3 (ADSL2) and G.992.5 (ADSL2+) and can either auto-detect the best mode or lock it to just one option. Annex M is supported. SRA is also supported.
*Chipset: The currently shipping DSL-320B-Z1 units (at the time of writing, December 2017), and those shipped from approx 2015 onwards, use an old but capable MediaTek/TrendChip chipset. The older -D1 routers were Broadcom-based.
*VDSL2 is not supported, so these devices cannot be used with FTTC.
*Incorrect manufacturer’s defaults: The default settings shown in the router’s web admin user interface show <b>defaults that are questionable</b>. These settings should be fixed - see following section.
*TR-069 is not supported by AA on these devices, so they cannot automatically be remotely configured, monitored or upgraded by AA.
*It is vital that you <b>'''not expose the LAN-side ethernet interface to users on the LAN</b>''' unless all possible users and devices on the LAN are trusted, because of various critical security bugs in the modem in this respect. Because of such bugs, setting passwords on the modem’s admin web UI etc. is ''not enough''. If your router happens to prevent LAN-internal users from accessing the modem then so much the better, otherwise your main router’s facilities /, internal firewalling and access controls shouldcould be exploredexploited. A firmware upgrade to release v1.06 or higher could well help fix security problems concerning access without any administrative login. [ftp://ftp.dlink.eu/Products/dsl/dsl-320b/driver_software/DSL-320B_fw_revZ1_1-06_EU_multi_20150807.zip Firmware v1.06]
*Chipset: The currently shipping DSL-320B-Z1 units (at the time of writing, December 2017), and those shipped from approx 2015 onwards, use an old but capable MediaTek/TrendChip chipset. The older -D1D1” routers were Broadcom-based.
*Incorrect manufacturer’s defaults: The default settings shown in the router’s web admin user interface show <b>'''defaults that are questionable</b>very much sub-optimal'''. DSL bitswap is set to ''off'' by default according to the web admin user interface. These settings shouldneed to be fixedamended - see following section.
 
== Initial setup using the web admin interface ==
 
The manufacturer’s default settings shown in the router’s web admin user interface show defaults that are very much sub-optimal. It is important to enable the ‘<b>'''bitswap</b>'''’ option for best reliability and performance in most cases. (See also this [http://forum.kitz.co.uk/index.php?topic=13296.0 discussion of bitswap].) This default seems so odd that perhaps this is just a bug in the DLink software, and the bitswap feature really defaults to ‘enabled’. (Needs a volunteer to do reliability testing to compare the two cases.)
 
These settings need to be configured as follows:
<ul>
<li>ANNEX A/I/J/L/M</li>
<li>Bitswap - <b>'''enable</b>''' (very importentimportant)</li>
<li>SRA - <b>'''enable</b>''' (for future-proofing, but currently has no effect as SRA is not supported by ege.g. BT currently)</li></ul>
 
''Performance tip for long lines:'' If you have an extremely long phone line (>60 &nbsp;dB downstream attenuation) and you canhave usean ADSL2+ service, it is maybe worthwhile experimenting with setting the DSL mode/standard option to ‘ADSL 2’ (only) in the above list of options, that is, taking ADSL2+ out of the list of allowed standards, as opposed to allowing the modem to use ADSL2+, to see if this restriction gives a performance improvement. It will be a long process to get a meaningful comparison with take many restarts and many tests needed to confirm any possible performance difference between allowing and disallowing ADSL2+. If in any doubt always enable ADSL2+ or ‘auto' mode ie ADSL1/ADSL2/ADSL2+ ‘auto’ mode, where the modem will use ADSL2+ (which can support much higher best-case speeds than ADSL2) if the exchangeexchange’s DSLAM or MSAN supports ADSL2+ too. With one particular 65dB downstream attenuation line, no improvement was seen, but better results were seen on a somewhat shorter, better line.
 
== After each reset to factory settings ==
<p id="post-factory-reset">
After any reset to factory settings you will need to make the following change using the web admin user interface in order to get the device to work properly as a straight modem. (Factory default <code><nowiki>http://192.168.1.1</nowiki></code>, and your own ip address set to something suitable in that same /24 subnet, username=admin, password=admin.)</p>
 
 
‘SETUP’ (top horizontal navigation bar) &gt; Bridge Mode
 
<ul>
Go to “Setup” and “ADSL Setup” and there tick “Manual Setup”. Then tick “Bridge Mode”. The “Connection Type” should show “1483 Bridged IP LLC" and the VPI / VCI settings on that page should be set to VPI = 0, VCI = 38. See also article at [http://www.dlink.com/uk/en/support/faq/modems/dsl-modems/dsl_320b/how-to-setup-dsl-320b-revision-z1-in-bridge-mode bridge mode setup article at Dlink website].
<li>1483 Bridged IP <b>LLC</b>. Important note: The leaner PPPoEoEoA + RFC2684’s [obsoletes RFC1483] “Bridged+<b>VC-MUX</b>” header option does not seem to work with BT Wholesale and the modem failed to establish a link for some reason when this tested</li></ul>
 
If your modem is accessible by users on the LAN, see the notes on security and access given earlier. Ideally consider using your router’s firewall capabilities if possible to block access to the modem. Failing that upgrade the firmware - see earlier notes - and set a suitable administrative password (see the Maintenance menu).
 
''Performance tip'': the leaner PPPoEoEoA + RFC2684 [obsoletes RFC1483] section 6.2 + '''VC-MUX''' header option (“bridged PDUs: VC-MUX”) is always ''more efficient'' than or the same as the alternative “LLC” header option. Choose 1483 Bridged VC-MUX aka PPPoE VC-MUX in preference to LLC if your exchange supports it, for example if you are using a BT 21CN line or a TalkTalk line. If unsure, use PPPoE / 1483 Bridged IP VC-MUX if there are no problems, otherwise ask AA support. The actual effective speed improvement depends on the length of the packets being sent (because of the absorbing effect of ATM cell padding) and for some packet lengths the performance gain is zero.
 
Following this you will then also need to make the configuration changes described in the previous section.
== Resetting to factory settings ==
 
To reset the modem to factory settings, locate the reset button hole on the rear panel of the unit. With the modem powered on, use a paperclip to hold the button down forand 10keep secondsan eye on the status LED on the front of the unit. ReleaseWhen the status LED goes off release the reset button and the modem will go through its reboot process.
Wait about 30 seconds to access the modem. The default IPv4 address for the modem’s http admin user interface on the LAN is 192.168.1.1/24. Your own IPv4 address will need to be in the same subnet and different from that of the modem, iei.e. set to something in the range <code>192.168.1.2</code> - <code>.254</code>, so perhaps use <code>192.168.1.99</code>. You can then log in to the web admin interface using a web browser at <code><nowiki>http://192.168.1.1</nowiki></code>, username=admin, password=admin.
 
== Images ==
 
=== DLink DSL-320B-Z1 modem ===
[[Image:Dlink-dsl-320b-z1-rearview.png | thumb | left | 500px | The currently shipping (as of December 2017) DLink DSL-320B-Z1 modem, rear view]]
<br style="{{clear:both"/>}}
=== Rear view of obsolete ‑D1 modem ===
 
(The image below is of the older generation of routers.)
 
[[Image:DLINK_320B-reset.jpg| thumb | left | 500px | Rear view of obsolete pre-Z1 modem, showing blanked-off reset button]]
 
[[Category:AA Routers|Dlink]]
editor
699

edits