This is a rather strange one. There is packetloss when downloading, however the download is not filling the link, but there is still loss, this is unusual. This turned out to be congestion on the Virtual Path within BT, or it may have been miss-configured. It took our escalation staff 3 months to convince BT that the fault was within their network.
 
===Phone line half connected - DIS in one leg===
[[File:CQM-FTTC-DIS-in-one-leg.png|none|frame|FTTC running on just a single leg/wire]]
Here we have a perfectly good FTTC, running at 80M. However, in the evening the line goes rather crazy! Here is what happened:
*18:20 End user was doing some tidying up of wiring and accidental disconnected on of the wires that make up the pair used for the phone line
**The line dropped a few times and reconnected, but the sync speed dropped to from 20M up and 80M down to 600K up and 23M down!
*The line continued working for a short while, up until:
*19:20 where a backup job was started which started uploading data
**As the sync speed was so low, the backup filled the link and high latency (blue) ensued.
**At the point the end user noticed something was not right.
*Looking at the times on the graph gave a clue to the end user what had happened. They had accidentally disconnected one of the wires of the phone line and surprisingly the FTTC was actually still in sync, logged in and passing traffic - just at low speeds.
*20:00 The wiring was repaired and the FTTC came back in to sync at the usual high rates.
 
===Faulty Switch on the LAN===