editor
466
edits
This is the support site for Andrews & Arnold Ltd, a UK Internet provider. Information on these pages is generally for our customers but may be useful to others, enjoy!
m (The description says port range of 5000-5098, so make the rules match (i.e. not 5000-5999)) |
m (Use the proper IP range for current AAISP VoIP servers) |
||
As an example with 2 phones, the first phone uses inbound SIP port 5060 and incoming RTP ports 5062-5068, and the second phone uses inbound SIP port 5040 and incoming RTP ports 5042-5048. Using iptables, the required rules would be like:
/sbin/iptables -t nat -A PREROUTING -i eth0 -m udp -p udp -s 81.187.30.
/sbin/iptables -t nat -A PREROUTING -i eth0 -m udp -p udp -s 81.187.30.
See: [[VoIP NAT]]
|