ZyXEL GS1900-8: Difference between revisions

Back up to the Other Hardware Category
From AAISP Support Site
 
(20 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<indicator name="Hardware">[[File:icon-box.svg|link=:Category:Other Hardware|30px|Back up to the Other Hardware Category]]</indicator>

=Overview=
=Overview=
[[File:Img gs1900-8 p 150.jpg]]
The GS1900-8 is a fanless 8 port managed switch.

The GS1900-8 is a fanless 8 port gigabit managed switch. It has a web interface to set it up, and is ideal as a small VLAN capable switch.

There is also a Power over Ethernet version available, the GS1900-8HP, which has a larger PSU and supports PoE.


=Configuration=
=Configuration=
Line 26: Line 32:


==Accessing the switch==
==Accessing the switch==
*Set your computer to be on an IP in the subnet that the switch is in, eg, 192.168.1.100/255.255.255.0
*Set your computer to be on an IP in the subnet that the switch is in, e.g., 192.168.1.100/255.255.255.0
*In your browser, go to http://192.168.1.1
*In your browser, go to http://192.168.1.1
*Login with the default credentials as above
*Login with the default credentials as above




=VLAN Configuration for Bonding Multiple lines with a FireBrick=
==VLAN config==
When using with a FireBrick for bonding multiple lines we can use VLANS for each of the PPP sessions.
When using with a FireBrick for bonding multiple lines we can use VLANS for each of the PPP sessions.

We have created a config file and have also outlined the construction in configuring the switch for the VLANS.

==VLAN config==


We'll configure the switch as:
We'll configure the switch as:
Line 40: Line 50:
*Port 4 - VLAN 104, for ADSL line 4
*Port 4 - VLAN 104, for ADSL line 4
*Port 8 is for the FireBrick
*Port 8 is for the FireBrick

The modems are not VLAN-aware, or even if they are we don't need them to be. We'll set ports 1-4 to tag incoming packets with the correct VLAN, and to send packets to the modems as untagged.

Ports 5, 6 and 7 will be unused, these could be used to access the switch config if you wanted.


==Pre-prepared config file for FireBrick bonding==
==Pre-prepared config file for FireBrick bonding==
Line 46: Line 60:
*Download the config: [[File:ZyXELGS1900-8-FireBrickVLANs.cfg.zip]]
*Download the config: [[File:ZyXELGS1900-8-FireBrickVLANs.cfg.zip]]
*Unzip the 'ZyXELGS1900-8-FireBrickVLANs.cfg' file and save it to your computer.
*Unzip the 'ZyXELGS1900-8-FireBrickVLANs.cfg' file and save it to your computer.
*Log in to the switch
*Plug computer in to port 7
*Set computer to IP: 192.168.1.2 mask: 255.255.255.0
*Log in to the switch via http://192.168.1.1 with username: admin and password: 1234
*From the front page, click the Maintenance icon on the left
*From the front page, click the Maintenance icon on the left
**Click Configuration, then Restore
**Click Configuration, then Restore
**Select HTTP, and then Choose the file then click apply
**Select HTTP, and then Choose the file then click Apply (the file will be ZyXELGS1900-8-FireBrickVLANs.cfg)
*Wait a moment for the switch to load and reboot - about 20 seconds
*Plug the modems on to ports 1-4 and the FireBrick to port 8.
*Log back in to the switch and set the admin password!


==Creating the VLANs==
==Manually Creating the VLANs==
[[File:GS1900-VLANs.png|thumbnail|VLAN Port Configuration]]
*Click VLAN
*From the front page, Click VLAN
**Create a new VLAN, enter in 101, then Click Next
**Create a new VLAN, enter in 101, then Click Next
***Drag Port01 to the Untagged area
***Drag Port01 to the Untagged area
Line 58: Line 78:
***Click Next, then click Finish
***Click Next, then click Finish
*Click Save from the top/right corner of the web interface
*Click Save from the top/right corner of the web interface


[[File:GS1900-VLANs.png|thumbnail|none|VLAN Port Configuration]]



This process repeats for VLAN 102, 103, 104 but you use Port02 for VLAN 102, Port03 for VLAN 103, Port04 for VLAN 104... so:
This process repeats for VLAN 102, 103, 104 but you use Port02 for VLAN 102, Port03 for VLAN 103, Port04 for VLAN 104... so:
Line 85: Line 101:
***Click Next, then click Finish
***Click Next, then click Finish
*Click Save from the top/right corner of the web interface
*Click Save from the top/right corner of the web interface

*Set the PVID for ports 1-4. this makes the switch tag the packets from the Modems with the corresponding VLAN ID.
**From the front page left menu, Click VLAN then VLAN
**Click the Port Tab
**Tick Port 1, then click Edit
**Set PVID to 101.
*Repeat the above Port settings for ports 2, 3 and 4 using PVID 102, 103 and 104.


==Change admin password==
==Change admin password==
Line 95: Line 118:
==Further, Optional settings==
==Further, Optional settings==


===Name the switch:===
===Name the switch===
*From the front page, click the settings/Cog icon on the left
*From the front page, click the settings/Cog icon on the left
**Click System, then Information
**Click System, then Information
Line 102: Line 125:
*Click Save from the top/right corner of the web interface
*Click Save from the top/right corner of the web interface


===Set Names for your VLANs:===
===Set Names for your VLANs===
*From the front page, click the settings/Cog icon on the left
*From the front page, click the settings/Cog icon on the left
*Click VLAN, then VLAN
*Click VLAN, then VLAN
Line 118: Line 141:
*Repeat the above for ports 2, 3, and 4. For port 8, name that FireBrick.
*Repeat the above for ports 2, 3, and 4. For port 8, name that FireBrick.
*Click Save from the top/right corner of the web interface
*Click Save from the top/right corner of the web interface



[[Category:Other Hardware|ZyXEL GS1900-8 Managed switch]]

Latest revision as of 04:28, 27 February 2020


Overview

Img gs1900-8 p 150.jpg

The GS1900-8 is a fanless 8 port gigabit managed switch. It has a web interface to set it up, and is ideal as a small VLAN capable switch.

There is also a Power over Ethernet version available, the GS1900-8HP, which has a larger PSU and supports PoE.

Configuration

Factory Default Admin Username/Password

Note: If AAISP configured the switch then the credentials will be different

Default/Factory Password
IP: 192.168.1.1
Username: admin
Password: 1234

https is enabled by default, albeit with a certificate that will give browser warnings

When you make a change to the configuration you must click Save from the top/right corner of the web interface

Factory Reset

Hold in the reset button on the front for 10 seconds, release, and all the port lights will light up and the switch will reboot.

Accessing the switch

  • Set your computer to be on an IP in the subnet that the switch is in, e.g., 192.168.1.100/255.255.255.0
  • In your browser, go to http://192.168.1.1
  • Login with the default credentials as above


VLAN Configuration for Bonding Multiple lines with a FireBrick

When using with a FireBrick for bonding multiple lines we can use VLANS for each of the PPP sessions.

We have created a config file and have also outlined the construction in configuring the switch for the VLANS.

VLAN config

We'll configure the switch as:

  • Port 1 - VLAN 101, for ADSL line 1
  • Port 2 - VLAN 102, for ADSL line 2
  • Port 3 - VLAN 103, for ADSL line 3
  • Port 4 - VLAN 104, for ADSL line 4
  • Port 8 is for the FireBrick

The modems are not VLAN-aware, or even if they are we don't need them to be. We'll set ports 1-4 to tag incoming packets with the correct VLAN, and to send packets to the modems as untagged.

Ports 5, 6 and 7 will be unused, these could be used to access the switch config if you wanted.

Pre-prepared config file for FireBrick bonding

We have created a config file for the above config, it has the default admin password so that should be changed. To apply the config:

  • Download the config: File:ZyXELGS1900-8-FireBrickVLANs.cfg.zip
  • Unzip the 'ZyXELGS1900-8-FireBrickVLANs.cfg' file and save it to your computer.
  • Plug computer in to port 7
  • Set computer to IP: 192.168.1.2 mask: 255.255.255.0
  • Log in to the switch via http://192.168.1.1 with username: admin and password: 1234
  • From the front page, click the Maintenance icon on the left
    • Click Configuration, then Restore
    • Select HTTP, and then Choose the file then click Apply (the file will be ZyXELGS1900-8-FireBrickVLANs.cfg)
  • Wait a moment for the switch to load and reboot - about 20 seconds
  • Plug the modems on to ports 1-4 and the FireBrick to port 8.
  • Log back in to the switch and set the admin password!

Manually Creating the VLANs

VLAN Port Configuration
  • From the front page, Click VLAN
    • Create a new VLAN, enter in 101, then Click Next
      • Drag Port01 to the Untagged area
      • Drag Port08 to the tagged area
      • Click Next, then click Finish
  • Click Save from the top/right corner of the web interface

This process repeats for VLAN 102, 103, 104 but you use Port02 for VLAN 102, Port03 for VLAN 103, Port04 for VLAN 104... so:

  • From the front page, Click VLAN
    • Create a new VLAN, enter in 102, then Click Next
      • Drag Port02 to the Untagged area
      • Drag Port08 to the tagged area
      • Click Next, then click Finish
  • Click Save from the top/right corner of the web interface
  • From the front page, Click VLAN
    • Create a new VLAN, enter in 103, then Click Next
      • Drag Port03 to the Untagged area
      • Drag Port08 to the tagged area
      • Click Next, then click Finish
  • Click Save from the top/right corner of the web interface
  • From the front page, Click VLAN
    • Create a new VLAN, enter in 104, then Click Next
      • Drag Port04 to the Untagged area
      • Drag Port08 to the tagged area
      • Click Next, then click Finish
  • Click Save from the top/right corner of the web interface
  • Set the PVID for ports 1-4. this makes the switch tag the packets from the Modems with the corresponding VLAN ID.
    • From the front page left menu, Click VLAN then VLAN
    • Click the Port Tab
    • Tick Port 1, then click Edit
    • Set PVID to 101.
  • Repeat the above Port settings for ports 2, 3 and 4 using PVID 102, 103 and 104.

Change admin password

  • From the front page, click the settings/Cog icon on the left
  • Click Management, then Users
    • Click the Modify icon next to the admin user
    • Enter in your new password and click Apply.
  • Click Save from the top/right corner of the web interface

Further, Optional settings

Name the switch

  • From the front page, click the settings/Cog icon on the left
    • Click System, then Information
    • Enter in Name, Location, Contact details as you wish
    • Click Apply
  • Click Save from the top/right corner of the web interface

Set Names for your VLANs

  • From the front page, click the settings/Cog icon on the left
  • Click VLAN, then VLAN
    • Click the modify icon to the right of VLAN 101
    • Change the name from VLAN0101 to, say, PPP101
    • Click Apply
  • Repeat for the other VLANs
  • Click Save from the top/right corner of the web interface

Name the Ethernet ports

  • From the front page, click the settings/Cog icon on the left
  • Click Port, then Port
    • Tick the bot next to Port 1, Click Edit
    • Set the name to, say, Modem1
  • Repeat the above for ports 2, 3, and 4. For port 8, name that FireBrick.
  • Click Save from the top/right corner of the web interface