Although you can now go on the internet fine, If you look at the RRD graphs or consult the gateway status page you will notice the status is either marked as offline or unknown.
This is a case because the script currently configuring apinger (the process that monitors the gateways) is buggy and currently does not cope very well with
Another problem is that for [[IPv6]] the AAISP gateway will currently not reply to pings on its local link address (and it is the one used for routing the traffic, so it is reachable!). So you have to manually set the monitor address to be 2001:8b0:0:81::51bb:51bb (which is the [[IPv6]] address of clueless.aa.net.uk). But even that won't initially work because even if you set the routable address, apinger is told to use the local link address as the source, meaning you will never get the response...
|