Jump to content

This is the support site for Andrews & Arnold Ltd, a UK Internet provider. Information on these pages is generally for our customers but may be useful to others, enjoy!

Router - ZyXEL P660HW-T1: Difference between revisions

m
no edit summary
mNo edit summary
mNo edit summary
 
(2 intermediate revisions by the same user not shown)
 
Telnet in, then type:
"sys edit autoexec.net"
Press "i"
You should see a colon
When you see the colon, type the following command:
"wan ghs set annex m"
Press enter, then press "x".
 
You can verify that autoexec.net contains the new command by typing "sys view autoexec.net".
sys view autoexec.net
 
After a reboot, the upstream sync rate should be increased, at the expense of some downstream.
 
 
[[Category:Router3rd Party Routers|ZyXEL]]
autoreview, Bureaucrats, editor, Interface administrators, reviewer, Administrators
12,274

edits