This shows the line is '''In Sync''', with an '''Up Sync''' of 854Kb/s, and a '''Down Sync''' of 6551Kb/s.
 
<pre>
BT Test xDSL Status Check:Pass OK.pass OK. Circuit In Sync
BRAS=5000Kb/s FTR=6374Kb/s MSR=7968Kb/s ServOpt=1 I/L=A
Up Sync=448Kb/s LoopLoss=21dB SNR=24dB HIGH ErrSec=0 HECErr=0 Cells=928584990
Down Sync=6144Kb/s '''FTB''' LoopLoss=33dB SNR=10dB ErrSec=0 HECErr=0 Cells=-1335203176
</pre>
This one shows that the line has a FTB - Fault Threshold Breach - ie, the Down Sync (6,144) is less than the Fault Threshold Rate (6,374). The line speed is below what it should be and would need looking in to. See: [:Category:Slow_ADSL]
 
 