==Configuring the S685IP==
 
If there are problems in setting up the S685IP it is easiest to start from a factory reset condition. This can
Starting from a factory reset, the following items need to be set using the web server in the base unit.
 
===IP address: ===
By default the base unit picks up an ip address using DHCP. This can be over-ridden by
connecting to "Settings -> IP Configuration", selecting "Static" and filling in the address details as required.
 
 
===Registration with AAISP:===
Select menu "Settings -> Telephony -> Connections" and click the "Edit" button for
IP1. Then click the "Show Advanced Settings" button and fill in the following fields:
 
===Authentication Name: <aaisp phone number> ===
(this can be in either UK or international format, for example
+44203095nnnn or 0203095nnnn )
 
===Authentication password: <password> ===
(This is the same password that is set on the AAISP control pages for this
number. Some non-alphanumeric characters can cause registration failure. In particular avoid "#" and "/")
 
 
=== Audio settings:===
In menu "Settings -> Telephony -> Audio" select "Voice Quality - Own Codec preference". For "IP1" remove all
codecs except "G.711 a law". This setting will generally give the best audio quality.
 
=== Other settings:===
If there are problems with recognition of dtmf tones by other systems consider setting "RFC2833" in the "Settings
-> Telephony -> Advanced Settings" menu. Avoid using "Audio".