(Created page with "==Phones and Versions Tested== {| class="wikitable" !colspan="3"|Linksys Versions tested |- !Model !Version !Notes |- |SPA-941 |5.1.8 | |}")
 
|
|}
 
 
==Configuration:==
Log in the the Web Interface, and go to Admin Login and Advanced. The settings to change from the factory settings would be:
 
{| class="wikitable"
!colspan="2"|Linksys SPA-941 Ext 1 Settings
|-
!Setting
!Value
|-
|Proxy:
|on
|-
|Outbound Proxy:
|voiceless.aa.net.uk
|-
|Use Outbound Proxy:
|Yes
|-
|Registrar
|voiceless.aa.net.uk
|-
|Display Name:
|Your Name, etc.
|-
|User ID:
|Your Number
|-
|Password
|Your Password
|-
|Preferred Codec:
|G711a
|-
|Use Pref Codec Only:
|Yes
|}
 