Sending SMS to the SIP2SIM service can be done via our gateway/api and we accept UTF-8 which we will convert as needed in to the necessary GSM character coding scheme and split for multi part messages automatically.
Sending SMS to the SIP2SIM service can be done via our gateway/api and we accept UTF-8 which we will convert as needed in to the necessary GSM character coding scheme and split for multi part messages automatically.



===SMS error codes===

* -201 no target found for incoming SMS to customer
* -204 error while HTTP posting to customer's server
* -202 and -203 invalid destination email address
* -301 no destination number
* -302 and -303 no SMS content to deliver
* -304 this is a status report, not a normal SMS
* -305 message billing error
* -306 too many message parts
* -702 -703 -704 usually multi-part message waiting for more parts, in different stages of routing. If that's the final return code it means parts went missing.
* -801 and -802 are decoding errors while packing to TPDUs
* -803 originator address not allowed