Telnet in, then type:
" sys edit autoexec.net"
Press "i"
You should see a colon
When you see the colon, type the following command:
" w dmt2 set largeD=2"
Press enter, then press "x".
 
You can verify that autoexec.net contains the new command by typing "sys view autoexec.net".
sys view autoexec.net"
 
After a reboot, the sync rate should be increased.
 
Telnet in, then type:
"sys edit autoexec.net"
Press "i"
You should see a colon
When you see the colon, type the following command:
"wan ghs set annex m"
Press enter, then press "x".
 
You can verify that autoexec.net contains the new command by typing "sys view autoexec.net".
sys view autoexec.net
 
After a reboot, the upstream sync rate should be increased, at the expense of some downstream.
 
 