Jump to content

This is the support site for Andrews & Arnold Ltd, a UK Internet provider. Information on these pages is generally for our customers but may be useful to others, enjoy!

Status Tests: Difference between revisions

Content deleted Content added
AA-Andrew (talk | contribs)
Created page with " ==BT Sync Status Test== *Available on BT ADSL lines This will report back the current sync status of the line, including error counts. This is non-intrusive and should not ca..."
 
AA-Andrew (talk | contribs)
mNo edit summary
Line 1: Line 1:

==BT Sync Status Test==
==BT Sync Status Test==
*Available on BT ADSL lines
*Available on BT ADSL lines
Line 12: Line 11:




==FTTC Line Tests==
==FTTC 'End to End' Tests==
*Available on BT FTTC/FTTP lines.
This will run FTTC/FTTP specific tests and will suggest if it finds a fault or not.

Example result:
BT Test E2E Access Test/DCN:Inconclusive OR test pass. Unable to find the fault.
Down:40.0 (39.9/39.7/39.9) Up:10.0 (10.0/10.0/10.0)
NA 0.128M-40M Downstream, Interleaving Off - 0.128M-10M Upstream, Interleaving Off
In Sync Pass:GTC_FTTC_SERVICE_0000 GEA service test completed and no fault found .

If the test says
Down:40.0 (//) Up:10.0 (//)
...Then the line is probably not in sync (no sync figures given)

[[Category:Line Tests]]