==BT Sync Status Test==
==BT Sync Status Test==

*Available on BT ADSL lines
*Available on BT ADSL lines.
This will report back the current sync status of the line, including error counts. This is non-intrusive and should not cause the line to drop.
This will report back the current sync status of the line, including error counts. This is non-intrusive and should not cause the line to drop.


Example output:
Example output:
<pre>
BT Test xDSL Status Check:Pass Standalone sub test passed successfully.Pass OK. Circuit In Sync
BT Test xDSL Status Check:Pass Standalone sub test passed successfully. Pass OK. Circuit In Sync.
BRAS=5779kbit/s FTR=6502kbit/s MSR=8128kbit/s ServOpt=1 I/L=A
BRAS=5779kbit/s FTR=6502kbit/s MSR=8128kbit/s ServOpt=1 I/L=A
Up Sync=854kbit/s LoopLoss=22.6&nbsp;dB SNR=17.5&nbsp;dB ErrSec=0 HECErr=0 Cells=1677609
Down Sync=6551kbit/s LoopLoss=40.8&nbsp;dB SNR=13.5&nbsp;dB ErrSec=0 HECErr=N/A Cells=4001712
Up Sync=854kbit/s LoopLoss=22.6 dB SNR=17.5 dB ErrSec=0 HECErr=0 Cells=1677609
Down Sync=6551kbit/s LoopLoss=40.8 dB SNR=13.5 dB ErrSec=0 HECErr=N/A Cells=4001712
This shows the line is In Sync, with a Up sync of 854Kb/s, and down od 6.551Kb/s
</pre>
This shows the line is '''In Sync''', with an '''Up Sync''' of 854Kb/s, and a '''Down Sync''' of 6551Kb/s.



==FTTC End to End Test==


==FTTC 'End to End' Tests==
*Available on BT FTTC/FTTP lines.
*Available on BT FTTC/FTTP lines.
This will run FTTC/FTTP specific tests and will suggest if it finds a fault or not.
This will run FTTC/FTTP specific tests and will suggest if it finds a fault or not.


Example result:
Example result:
<pre>
BT Test E2E Access Test/DCN:Inconclusive OR test pass. Unable to find the fault.
BT Test E2E Access Test/DCN:Inconclusive OR test pass. Unable to find the fault.
Down:40.0 (39.9/39.7/39.9) Up:10.0 (10.0/10.0/10.0)
Down:40.0 (39.7/39.9/40.0) Up:10.0 (9.9/9.9/9.9)
NA 0.128M-40M Downstream, Interleaving Off - 0.128M-10M Upstream, Interleaving Off
NA 0.128M-40M Downstream, Interleaving Off - 0.128M-10M Upstream, Interleaving Off.
In Sync Pass:GTC_FTTC_SERVICE_0000 GEA service test completed and no fault found .
In Sync Pass:GTC_FTTC_SERVICE_0000 GEA service test completed and no fault found.
</pre>


If the test says
If the test says...
<pre>
Down:40.0 (//) Up:10.0 (//)
Down:40.0 (//) Up:10.0 (//)
...Then the line is probably not in sync (no sync figures given)
</pre>
...then the line is probably not in sync (no sync figures given).


[[Category:Line Tests]]
[[Category:Line Tests]]

Revision as of 00:00, 8 March 2015

BT Sync Status Test

  • Available on BT ADSL lines.

This will report back the current sync status of the line, including error counts. This is non-intrusive and should not cause the line to drop.

Example output:

BT Test xDSL Status Check:Pass Standalone sub test passed successfully. Pass OK. Circuit In Sync.
BRAS=5779kbit/s FTR=6502kbit/s MSR=8128kbit/s ServOpt=1 I/L=A
Up Sync=854kbit/s LoopLoss=22.6 dB SNR=17.5 dB ErrSec=0 HECErr=0 Cells=1677609
Down Sync=6551kbit/s LoopLoss=40.8 dB SNR=13.5 dB ErrSec=0 HECErr=N/A Cells=4001712

This shows the line is In Sync, with an Up Sync of 854Kb/s, and a Down Sync of 6551Kb/s.


FTTC End to End Test

  • Available on BT FTTC/FTTP lines.

This will run FTTC/FTTP specific tests and will suggest if it finds a fault or not.

Example result:

BT Test E2E Access Test/DCN:Inconclusive OR test pass. Unable to find the fault.
Down:40.0 (39.7/39.9/40.0) Up:10.0 (9.9/9.9/9.9)
NA 0.128M-40M Downstream, Interleaving Off - 0.128M-10M Upstream, Interleaving Off.
In Sync Pass:GTC_FTTC_SERVICE_0000 GEA service test completed and no fault found.

If the test says...

Down:40.0 (//) Up:10.0 (//)

...then the line is probably not in sync (no sync figures given).