==End to End tests==
*Available on BT FTTC/FTTP lines.
This will run FTTC/FTTP specific tests and will suggest if it finds a fault or not.
 
Example result:
BT Test E2E Access Test/DCN:Inconclusive OR test pass. Unable to find the fault.
Down:40.0 (39.9/39.7/39.9) Up:10.0 (10.0/10.0/10.0)
NA 0.128M-40M Downstream, Interleaving Off - 0.128M-10M Upstream, Interleaving Off
In Sync Pass:GTC_FTTC_SERVICE_0000 GEA service test completed and no fault found .
 