DGA0122 Remove tr069

Back up to the Technicolor_DGA0122 Page
From AAISP Support Site
Revision as of 11:44, 21 December 2020 by AA-Andrew (talk | contribs) (Created page with "<indicator name="Front">link=:Category:Technicolor_DGA0122|30px|Back up to the Technicolor_DGA0122 Page</indicator> Category:Technicolor_DGA0122 By...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


By default, the router will hard coded with the Andrews & Arnold TR069 server and default ppp login details. These are set to enable the router to be configured automatically when new or when reset. These will remain even after a factory reset.

To remove the Andrews & Arnold log in to the router with username engineer, and go to the page /isp.ip Here you can delete the settings and also add new ones if needed.