Phones and Versions Tested
Linksys Versions tested
Model
Version
Notes
SPA-941
5.1.8
Feature Notes
Supports 302 Redirect
?
Tested on FireBrick SIP Server
Yes
IPv6 Support
No
Configuration:
Log in the the Web Interface, and go to Admin Login and Advanced. The settings to change from the factory settings would be:
Linksys SPA-941 Ext 1 Settings
Setting
Value
Proxy:
on
Outbound Proxy:
voiceless.aa.net.uk
Use Outbound Proxy:
Yes
Registrar
voiceless.aa.net.uk
Display Name:
Your Name, etc.
User ID:
Your Number
Password
Your Password
Preferred Codec:
G711a
Use Pref Codec Only:
Yes
Don't forget to set http/admin passwords etc, so as to secure the web interface from the public.