LinksysSPA941.jpg

Phones and Versions Tested

Linksys Versions tested
Model Version Notes
SPA-941 5.1.8

Configuration:

Log in the the Web Interface, and go to Admin Login and Advanced. The settings to change from the factory settings would be:

Linksys SPA-941 Ext 1 Settings
Setting Value
Proxy: on
Outbound Proxy: voiceless.aa.net.uk
Use Outbound Proxy: Yes
Registrar voiceless.aa.net.uk
Display Name: Your Name, etc.
User ID: Your Number
Password Your Password
Preferred Codec: G711a
Use Pref Codec Only: Yes

Don't forget to set http/admin passwords etc, so as to secure the web interface from the public.

Linksysspa941-config.png