Phones and Versions Tested
Linksys Versions tested
|
Model
|
Version
|
Notes
|
SPA-941
|
5.1.8
|
|
Feature Notes
|
Supports 302 Redirect
|
?
|
Tested on FireBrick SIP Server
|
Yes
|
IPv6 Support
|
No
|
Configuration:
Log in the the Web Interface, and go to Admin Login and Advanced. The settings to change from the factory settings would be:
Linksys SPA-941 Ext 1 Settings
|
Setting
|
Value
|
Proxy:
|
on
|
Outbound Proxy:
|
voiceless.aa.net.uk
|
Use Outbound Proxy:
|
Yes
|
Registrar
|
voiceless.aa.net.uk
|
Display Name:
|
Your Name, etc.
|
User ID:
|
Your Number
|
Password
|
Your Password
|
Preferred Codec:
|
G711a
|
Use Pref Codec Only:
|
Yes
|
Don't forget to set http/admin passwords etc, so as to secure the web interface from the public.